Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Clin Appl Thromb Hemost ; 27: 10760296211052293, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34894779

RESUMEN

Heparin is one of the most widely used drugs in the world. It has been described as a lifesaving drug due to its roles in treating many serious diseases and illnesses including kidney dialysis, surgery, cardiac-invasive, heart attack, cardiac arrhythmia, acute coronary syndrome, pulmonary embolism, stroke, deep vein thrombosis, blood clot prevention, and many other related uses. Heparin drug products currently approved in the United States are obtained from porcine intestinal mucosa sourced from pigs, the majority of which is imported from China. However, due to the heparin contamination crisis (2008) and potential shortage and to safeguard the quality of current and future heparin supply chains including raw material, Food and Drug administration (FDA) posted a notification on its website titled "FDA Encourages Reintroduction of Bovine-Sourced Heparin". This perspective is intended to address the history of regulatory and scientific background of heparin drug products obtained from bovine and porcine sources and general recommendations for improving the quality of current heparin manufacturing process including Critical Quality Attributes (CQA), control management, process control, related tests, limits, etc. Additionally, a general plan with systematic steps is proposed for diversifying heparin supply chains by reintroduction of bovine sourced heparin to the US market.


Asunto(s)
Desarrollo de Medicamentos/métodos , Heparina/farmacología , Tromboembolia/tratamiento farmacológico , Animales , Anticoagulantes/farmacología , Bovinos , Humanos , Estados Unidos
2.
Nat Biotechnol ; 34(6): 625-30, 2016 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-27281424

RESUMEN

The contamination of the widely used lifesaving anticoagulant drug heparin in 2007 has drawn renewed attention to the challenges that are associated with the characterization, quality control and standardization of complex biological medicines from natural sources. Heparin is a linear, highly sulfated polysaccharide consisting of alternating glucosamine and uronic acid monosaccharide residues. Heparin has been used successfully as an injectable antithrombotic medicine since the 1930s, and its isolation from animal sources (primarily porcine intestine) as well as its manufacturing processes have not changed substantially since its introduction. The 2007 heparin contamination crisis resulted in several deaths in the United States and hundreds of adverse reactions worldwide, revealing the vulnerability of a complex global supply chain to sophisticated adulteration. This Perspective discusses how the US Food and Drug Administration (FDA), the United States Pharmacopeial Convention (USP) and international stakeholders collaborated to redefine quality expectations for heparin, thus making an important natural product better controlled and less susceptible to economically motivated adulteration.


Asunto(s)
Contaminación de Medicamentos/legislación & jurisprudencia , Contaminación de Medicamentos/prevención & control , Salud Global/legislación & jurisprudencia , Heparina/normas , Farmacopeas como Asunto/normas , Vigilancia de Productos Comercializados/normas , Salud Global/normas , Regulación Gubernamental , Legislación de Medicamentos , Guías de Práctica Clínica como Asunto , Estados Unidos , United States Food and Drug Administration/legislación & jurisprudencia
3.
Clin Cancer Res ; 21(16): 3586-90, 2015 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-26275952

RESUMEN

On November 13, 2013, the FDA granted accelerated approval to ibrutinib (IMBRUVICA capsules; Pharmacyclics, Inc.) for the treatment of patients with mantle cell lymphoma (MCL) who have received at least one prior therapy. On February 12, 2014, the FDA granted accelerated approval for the treatment of patients with chronic lymphocytic leukemia (CLL) who have received at least one prior therapy. Ibrutinib is a first-in-class Bruton's tyrosine kinase (BTK) inhibitor that received all four expedited programs of the FDA: Fast-Track designation, Breakthrough Therapy designation, Priority Review, and Accelerated Approval. Both approvals were based on overall response rate (ORR) and duration of response (DOR) in single-arm clinical trials in patients with prior treatment. In MCL (N = 111), the complete and partial response rates were 17.1% and 48.6%, respectively, for an ORR of 65.8% [95% confidence interval (CI), 56.2%-74.5%]. The median DOR was 17.5 months (95% CI, 15.8-not reached). In CLL (N = 48), the ORR was 58.3% (95% CI, 43.2%-72.4%), and the DOR ranged from 5.6 to 24.2 months. The most common adverse reactions (≥ 30% in either trial) were thrombocytopenia, diarrhea, neutropenia, bruising, upper respiratory tract infection, anemia, fatigue, musculoskeletal pain, peripheral edema, and nausea.


Asunto(s)
Leucemia Linfocítica Crónica de Células B/tratamiento farmacológico , Linfoma de Células del Manto/tratamiento farmacológico , Pirazoles/farmacocinética , Pirazoles/uso terapéutico , Pirimidinas/farmacocinética , Pirimidinas/uso terapéutico , Adenina/análogos & derivados , Anciano , Ensayos Clínicos como Asunto , Aprobación de Drogas/legislación & jurisprudencia , Femenino , Humanos , Leucemia Linfocítica Crónica de Células B/patología , Linfoma de Células del Manto/patología , Masculino , Persona de Mediana Edad , Piperidinas , Inhibidores de Proteínas Quinasas/uso terapéutico , Pirazoles/efectos adversos , Pirimidinas/efectos adversos , Estados Unidos
4.
Clin Cancer Res ; 21(11): 2436-9, 2015 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-25754348

RESUMEN

On April 29, 2014, the FDA granted accelerated approval to ceritinib (ZYKADIA; Novartis Pharmaceuticals Corporation), a breakthrough therapy-designated drug, for the treatment of patients with anaplastic lymphoma kinase (ALK)-positive, metastatic non-small cell lung cancer (NSCLC) who have progressed on or are intolerant to crizotinib. The approval was based on a single-arm multicenter trial enrolling 163 patients with metastatic ALK-positive NSCLC who had disease progression on (91%) or intolerance to crizotinib. Patients received ceritinib at a starting dose of 750 mg orally once daily. The objective response rate (ORR) by a blinded independent review committee was 44% (95% CI, 36-52), and the median duration of response (DOR) was 7.1 months. The ORR by investigator assessment was similar. Safety was evaluated in 255 patients. The most common adverse reactions and laboratory abnormalities included diarrhea (86%), nausea (80%), increased alanine transaminase (80%), increased aspartate transaminase (75%), vomiting (60%), increased glucose (49%), and increased lipase (28%). Although 74% of patients required at least one dose reduction or interruption due to adverse reactions, the discontinuation rate due to adverse reactions was low (10%). With this safety profile, the benefit-risk analysis was considered favorable because of the clinically meaningful ORR and DOR.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Aprobación de Drogas , Pirimidinas/uso terapéutico , Proteínas Tirosina Quinasas Receptoras/genética , Sulfonas/uso terapéutico , Anciano , Quinasa de Linfoma Anaplásico , Carcinoma de Pulmón de Células no Pequeñas/genética , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/clasificación , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pirimidinas/efectos adversos , Medición de Riesgo , Sulfonas/efectos adversos , Estados Unidos , United States Food and Drug Administration
5.
Clin Cancer Res ; 20(17): 4436-41, 2014 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-24879797

RESUMEN

On February 22, 2013, the FDA licensed ado-trastuzumab emtansine (Kadcyla; Genentech, Inc.) for use as a single agent for the treatment of patients with human epidermal growth factor receptor 2 (HER2)-positive metastatic breast cancer (MBC) who previously received trastuzumab and a taxane, separately or in combination. The clinical basis for licensure was a phase III trial in 991 patients with HER2-positive MBC that randomly allocated patients to receive ado-trastuzumab emtansine (n=495) or lapatinib in combination with capecitabine (n=496). The coprimary endpoints were progression-free survival (PFS) based on tumor assessments by an independent review committee and overall survival (OS). Statistically significant improvements in PFS and OS were observed in patients receiving ado-trastuzumab emtansine compared with patients receiving lapatinib plus capecitabine [difference in PFS medians of 3.2 months, HR, 0.65 (95% confidence interval, CI, 0.55-0.77), P<0.0001 and difference in OS medians of 5.8 months, HR, 0.68 (95% CI, 0.55-0.85), P=0.0006]. The most common adverse reactions in patients receiving ado-trastuzumab emtansine were fatigue, nausea, musculoskeletal pain, thrombocytopenia, headache, increased aminotransferase levels, and constipation. Other significant adverse reactions included hepatobiliary disorders and left ventricular dysfunction. Given the PFS and OS results, the benefit-risk profile was considered favorable.


Asunto(s)
Anticuerpos Monoclonales Humanizados/administración & dosificación , Neoplasias de la Mama/tratamiento farmacológico , Maitansina/análogos & derivados , Receptor ErbB-2/genética , Ado-Trastuzumab Emtansina , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Monoclonales Humanizados/efectos adversos , Neoplasias de la Mama/genética , Neoplasias de la Mama/patología , Supervivencia sin Enfermedad , Aprobación de Drogas , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Femenino , Humanos , Maitansina/administración & dosificación , Maitansina/efectos adversos , Persona de Mediana Edad , Trastuzumab , Estados Unidos , United States Food and Drug Administration
7.
Clin Cancer Res ; 20(1): 9-14, 2014 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-24190979

RESUMEN

On May 15, 2013, the U.S. Food and Drug Administration (FDA) approved radium Ra 223 dichloride (Ra-223; Xofigo injection; Bayer HealthCare Pharmaceuticals Inc.) for the treatment of patients with castration-resistant prostate cancer (CRPC), symptomatic bone metastases, and no known visceral metastatic disease. The FDA review was based on clinical trial BC1-06, which randomly allocated patients (2:1) to either Ra-223 plus best standard of care (BSoC) or placebo plus BSoC. The primary endpoint was overall survival (OS) with a key secondary endpoint of time to first symptomatic skeletal event (SSE). A statistically significant improvement in OS was demonstrated [HR, 0.70; 95% confidence interval, 0.55-0.88, P = 0.0019]. At the prespecified interim analysis, the median OS durations were 14.0 and 11.2 months in the Ra-223 and placebo arms, respectively. The improvement in OS was supported by a delay in time to first SSE favoring the Ra-223 arm. The most common (>10%) adverse reactions in patients receiving Ra-223 were nausea, diarrhea, vomiting, and peripheral edema. The most common (>10%) hematologic laboratory abnormalities were anemia, lymphocytopenia, leukopenia, thrombocytopenia, and neutropenia. Ra-223 is the first α-emitting radiotherapeutic and the first radiopharmaceutical to demonstrate an OS advantage in metastatic prostate cancer.


Asunto(s)
Neoplasias Óseas/radioterapia , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Radiofármacos/uso terapéutico , Radio (Elemento)/uso terapéutico , Anciano , Animales , Neoplasias Óseas/mortalidad , Neoplasias Óseas/secundario , Método Doble Ciego , Aprobación de Drogas , Humanos , Estimación de Kaplan-Meier , Masculino , Neoplasias de la Próstata Resistentes a la Castración/mortalidad , Neoplasias de la Próstata Resistentes a la Castración/patología , Radioisótopos/efectos adversos , Radioisótopos/uso terapéutico , Radiofármacos/efectos adversos , Radio (Elemento)/efectos adversos , Resultado del Tratamiento , Estados Unidos , United States Food and Drug Administration
8.
J Pharm Biomed Anal ; 85: 99-107, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23917037

RESUMEN

During the 2007-2008 heparin crisis it was found that the United States Pharmacopeia (USP) testing monograph for heparin sodium or low molecular weight heparins did not detect the presence of the contaminant, oversulfated chondroitin sulfate (OSCS). In response to this concern, new tests and specifications were developed by the Food and Drug Administration (FDA) and USP and put in place to detect not only the contaminant OSCS, but also to improve assurance of quality and purity of these drug products. The USP monographs for the low molecular weight heparins (LMWHs) approved for use in the United States (dalteparin, tinzaparin and enoxaparin) are also undergoing revision to include many of the same tests used for heparin sodium, including; one-dimensional (1D) 500 MHz (1)H NMR, SAX-HPLC, percent galactosamine in total hexosamine and anticoagulation time assays with purified Factor IIa or Factor Xa. These tests represent orthogonal approaches for heparin identification, measurement of bioactivity and for detection of process impurities or contaminants in these drug products. Here we describe results from a survey of multiple lots from three types of LMWHs in the US market which were collected after the 2009 heparin sodium monograph revision. In addition, innovator and generic versions of formulated enoxaparin products purchased in 2011 are compared using these tests and found to be highly similar within the discriminating power of the assays applied.


Asunto(s)
Contaminación de Medicamentos , Heparina de Bajo-Peso-Molecular/análisis , Cromatografía Líquida de Alta Presión , Electroforesis Capilar , Enoxaparina/farmacología , Heparina de Bajo-Peso-Molecular/farmacología , Heparina de Bajo-Peso-Molecular/normas , Espectroscopía de Resonancia Magnética
9.
J Pharm Biomed Anal ; 67-68: 42-50, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22633605

RESUMEN

Previously, the FDA validated a method to assess the structure and composition of heparin products by separating and quantifying disaccharide level digests by reverse-phase-ion-pairing liquid chromatography (RPIP-HPLC) coupled to a low resolution and low sensitivity ion trap mass-spectrometer. Here, improved separation, information content and sensitivity were obtained through the use of reverse phase ion-pairing ultra-high pressure liquid chromatography (RPIP-UHPLC) coupled with a quadrupole time-of-flight (Q-TOF) mass spectrometer. Thus, with the new method, improved structural characterization of the same 20 lots of heparin sodium active pharmaceutical ingredients (APIs) as were analyzed in the previous work were obtained. In addition, for the first time, 10 low molecular weight heparin (LMWH) lots were characterized representing multiple lots manufactured by three different processes (dalteparin, tinzaparin or enoxaparin). In this study, UHPLC separation conditions and the enzymatic digesting protocol were optimized for analysis of disaccharide level digests of heparin and positive and negative electrospray ionization (ESI) modes were tested. The negative ion mode ESI analysis was found to be superior to the positive ion mode for these measurements, and a combination of heparin lyase II and III were optimal for heparin digestion. The data obtained establishes the normal variation in the composition of heparin sodium or LMWHs in this assay. These values are useful as possible product benchmarks and for surveillance of the heparin products being imported into the US market.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Heparina/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Límite de Detección
10.
Anal Bioanal Chem ; 401(8): 2445-54, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21901459

RESUMEN

We evaluated polyacrylamide gel electrophoresis (PAGE) and size exclusion chromatography coupled with multi-angle laser light scattering (SEC-MALLS) approaches to determine weight-average molecular weight (M(w)) and polydispersity (PD) of heparins. A set of unfractionated heparin sodium (UFH) and low-molecular-weight heparin (LMWH) samples obtained from nine manufacturers which supply the US market were assessed. For SEC-MALLS, we measured values for water content, refractive index increment (dn/dc), and the second virial coefficient (A(2)) for each sample prior to molecular weight assessment. For UFH, a mean ± standard deviation value for M(w) of 16,773 ± 797 was observed with a range of 15,620 to 18,363 (n = 20, run in triplicate). For LMWHs by SEC-MALLS, we measured mean M(w) values for dalteparin, tinzaparin, and enoxaparin of 6,717 ± 71 (n = 4), 6,670 ± 417 (n = 3), and 3,959 ± 145 (n = 3), respectively. PAGE analysis of the same UFH, dalteparin, tinzaparin, and enoxaparin samples showed values of 16,135 ± 643 (n = 20), 5,845 ± 45 (n = 4), 6,049 ± 95 (n = 3), and 4,772 ± 69 (n = 3), respectively. These orthogonal measurements are the first M(w) results obtained with a large heparin sample set on product being marketed after the heparin crisis of 2008 changed the level of scrutiny of this drug class. In this study, we compare our new data set to samples analyzed over 10 years earlier. In addition, we found that the PAGE analysis of heparinase digested UFH and neat LMWH samples yield characteristic patterns that provide a facile approach for identification and assessment of drug quality and uniformity.


Asunto(s)
Anticoagulantes/química , Cromatografía en Gel/métodos , Electroforesis en Gel de Poliacrilamida/métodos , Liasa de Heparina/metabolismo , Heparina de Bajo-Peso-Molecular/química , Heparina/química , Anticoagulantes/metabolismo , Heparina/metabolismo , Heparina de Bajo-Peso-Molecular/metabolismo , Luz , Peso Molecular , Refractometría , Dispersión de Radiación
11.
Anal Bioanal Chem ; 401(3): 939-55, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21678118

RESUMEN

Chemometric analysis of a set of one-dimensional (1D) (1)H nuclear magnetic resonance (NMR) spectral data for heparin sodium active pharmaceutical ingredient (API) samples was employed to distinguish USP-grade heparin samples from those containing oversulfated chondroitin sulfate (OSCS) contaminant and/or unacceptable levels of dermatan sulfate (DS) impurity. Three chemometric pattern recognition approaches were implemented: classification and regression tree (CART), artificial neural network (ANN), and support vector machine (SVM). Heparin sodium samples from various manufacturers were analyzed in 2008 and 2009 by 1D (1)H NMR, strong anion-exchange high-performance liquid chromatography, and percent galactosamine in total hexosamine tests. Based on these data, the samples were divided into three groups: Heparin, DS ≤ 1.0% and OSCS = 0%; DS, DS > 1.0% and OSCS = 0%; and OSCS, OSCS > 0% with any content of DS. Three data sets corresponding to different chemical shift regions (1.95-2.20, 3.10-5.70, and 1.95-5.70 ppm) were evaluated. While all three chemometric approaches were able to effectively model the data in the 1.95-2.20 ppm region, SVM was found to substantially outperform CART and ANN for data in the 3.10-5.70 ppm region in terms of classification success rate. A 100% prediction rate was frequently achieved for discrimination between heparin and OSCS samples. The majority of classification errors between heparin and DS involved cases where the DS content was close to the 1.0% DS borderline between the two classes. When these borderline samples were removed, nearly perfect classification results were attained. Satisfactory results were achieved when the resulting models were challenged by test samples containing blends of heparin APIs spiked with non-, partially, or fully oversulfated chondroitin sulfate A, heparan sulfate, or DS at the 1.0%, 5.0%, and 10.0% (w/w) levels. This study demonstrated that the combination of 1D (1)H NMR spectroscopy with multivariate chemometric methods is a nonsubjective, statistics-based approach for heparin quality control and purity assessment that, once standardized, minimizes the need for expert analysts.


Asunto(s)
Contaminación de Medicamentos , Heparina/química , Espectroscopía de Resonancia Magnética , Anticoagulantes/química , Sulfatos de Condroitina/análisis , Sulfatos de Condroitina/química , Dermatán Sulfato/análisis , Dermatán Sulfato/química , Humanos , Control de Calidad
12.
Anal Chem ; 83(3): 1030-9, 2011 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-21192734

RESUMEN

To differentiate heparin samples with varying amounts of dermatan sulfate (DS) impurities and oversulfated chondroitin sulfate (OSCS) contaminants, proton NMR spectral data for heparin sodium active pharmaceutical ingredient samples from different manufacturers were analyzed using multivariate chemometric techniques. A total of 168 samples were divided into three groups: (a) Heparin, [DS] ≤ 1.0% and [OSCS] = 0%; (b) DS, [DS] > 1.0% and [OSCS] = 0%; (c) OSCS, [OSCS] > 0% with any content of DS. The chemometric models were constructed and validated using two well-established methods: soft independent modeling of class analogy (SIMCA) and unequal class modeling (UNEQ). While SIMCA modeling was conducted using the entire set of variables extracted from the NMR spectral data, UNEQ modeling was combined with variable reduction using stepwise linear discriminant analysis to comply with the requirement that the number of samples per class exceed the number of variables in the model by at least 3-fold. Comparison of the results from these two modeling approaches revealed that UNEQ had greater sensitivity (fewer false positives) while SIMCA had greater specificity (fewer false negatives). For Heparin, DS, and OSCS, respectively, the sensitivity was 78% (56/72), 74% (37/50), and 85% (39/46) from SIMCA modeling and 88% (63/72), 90% (45/50), and 91% (42/46) from UNEQ modeling. Importantly, the specificity of both the SIMCA and UNEQ models was 100% (46/46) for Heparin with respect to OSCS; no OSCS-containing sample was misclassified as Heparin. The specificity of the SIMCA model (45/50, or 90%) was superior to that of the UNEQ model (27/50, or 54%) for Heparin with respect to DS samples. However, the overall prediction ability of the UNEQ model (85%) was notably better than that of the SIMCA model (76%) for the Heparin vs DS vs OSCS classes. The models were challenged with blends of heparin spiked with nonsulfated, partially sulfated, or fully oversulfated chondroitin sulfate A, dermatan sulfate, or heparan sulfate at the 1.0, 5.0, and 10.0 wt % levels. The results from the present study indicate that the combination of (1)H NMR spectral data and class modeling techniques (viz., SIMCA and UNEQ) represents a promising strategy for assessing the quality of commercial heparin samples with respect to impurities and contaminants. The methodologies show utility for applications beyond heparin to other complex products.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Preparaciones Farmacéuticas/análisis , Protones
13.
J Pharm Biomed Anal ; 54(5): 1020-9, 2011 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-21215547

RESUMEN

Heparin is a naturally produced, heterogeneous compound consisting of variably sulfated and acetylated repeating disaccharide units. The structural complexity of heparin complicates efforts to assess the purity of the compound, especially when differentiating between similar glycosaminoglycans. Recently, heparin sodium contaminated with oversulfated chondroitin sulfate A (OSCS) has been associated with a rapid and acute onset of an anaphylactic reaction. In addition, naturally occurring dermatan sulfate (DS) was found to be present in these and other heparin samples as an impurity due to incomplete purification. The present study was undertaken to determine whether chemometric analysis of these NMR spectral data would be useful for discrimination between USP-grade samples of heparin sodium API and those deemed unacceptable based on their levels of DS, OSCS, or both. Several multivariate chemometric methods for clustering and classification were evaluated; specifically, principal components analysis (PCA), partial least squares discriminant analysis (PLS-DA), linear discriminant analysis (LDA), and the k-nearest-neighbor (kNN) method. Data dimension reduction and variable selection techniques, implemented to avoid over-fitting the training set data, markedly improved the performance of the classification models. Under optimal conditions, a perfect classification (100% success rate) was attained on external test sets for the Heparin vs OSCS model. The predictive rates for the Heparin vs DS, Heparin vs [DS+OSCS], and Heparin vs DS vs OSCS models were 89%, 93%, and 90%, respectively. In most cases, misclassifications can be ascribed to the similarity in NMR chemical shifts of heparin and DS. Among the chemometric methods evaluated in this study, we found that the LDA models were superior to the PLS-DA and kNN models for classification. Taken together, the present results demonstrate the utility of chemometric methods when applied in combination with (1)H NMR spectral analysis for evaluating the quality of heparin APIs.


Asunto(s)
Sulfatos de Condroitina/aislamiento & purificación , Dermatán Sulfato/aislamiento & purificación , Contaminación de Medicamentos , Heparina/análisis , Espectroscopía de Resonancia Magnética/métodos , Cromatografía Líquida de Alta Presión , Heparina/química , Heparina/normas , Análisis de los Mínimos Cuadrados , Modelos Lineales , Espectroscopía de Resonancia Magnética/estadística & datos numéricos , Análisis Multivariante , Análisis de Componente Principal , Protones
14.
Anal Bioanal Chem ; 399(2): 581-91, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20680615

RESUMEN

During the 2007-2008 heparin crisis, it was found that the United States Pharmacopeia (USP) testing monograph for unfractionated heparin sodium (UFH) did not detect the presence of the contaminant, oversulfated chondroitin sulfate (OSCS) in heparin. In response to this concern, new tests and specifications were developed by the Food and Drug Administration (FDA) and USP and put in place to not only detect the contaminant OSCS but also to improve assurance of quality and purity of the drug product. Additional tests were also developed to monitor the heparin supply chain for other possible economically motivated additives or impurities. In 2009, a new USP monograph was put in place that includes 500 MHz (1)H NMR, SAX-HPLC, %galactosamine in total hexosamine, and anticoagulation time assays with purified factor IIa or factor Xa. These tests represent orthogonal approaches for UFH identification, measurement of bioactivity, and for detection of process impurities or contaminants in UFH. The FDA has applied these analytical approaches to the study of UFH active pharmaceutical ingredients in the marketplace. Here, we describe results from a comprehensive survey of UFH collected from seven different sources after the 2009 monograph revision and compare these data with results obtained on other heparin samples collected during the 2007-2008 crisis.


Asunto(s)
Anticoagulantes/química , Contaminación de Medicamentos , Heparina/química , Espectroscopía de Resonancia Magnética/métodos , Anticoagulantes/farmacología , Sulfatos de Condroitina/análisis , Cromatografía Líquida de Alta Presión/métodos , Electroforesis Capilar/métodos , Heparina/farmacología , Humanos , Control de Calidad , Estados Unidos , United States Food and Drug Administration
15.
Anal Bioanal Chem ; 399(2): 635-49, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20953772

RESUMEN

Heparin, a widely used anticoagulant primarily extracted from animal sources, contains varying amounts of galactosamine impurities. Currently, the United States Pharmacopeia (USP) monograph for heparin purity specifies that the weight percent of galactosamine (%Gal) may not exceed 1%. In the present study, multivariate regression (MVR) analysis of (1)H NMR spectral data obtained from heparin samples was employed to build quantitative models for the prediction of %Gal. MVR analysis was conducted using four separate methods: multiple linear regression, ridge regression, partial least squares regression, and support vector regression (SVR). Genetic algorithms and stepwise selection methods were applied for variable selection. In each case, two separate prediction models were constructed: a global model based on dataset A which contained the full range (0-10%) of galactosamine in the samples and a local model based on the subset dataset B for which the galactosamine level (0-2%) spanned the 1% USP limit. All four regression methods performed equally well for dataset A with low prediction errors under optimal conditions, whereas SVR was clearly superior among the four methods for dataset B. The results from this study show that (1)H NMR spectroscopy, already a USP requirement for the screening of contaminants in heparin, may offer utility as a rapid method for quantitative determination of %Gal in heparin samples when used in conjunction with MVR approaches.


Asunto(s)
Anticoagulantes/química , Contaminación de Medicamentos , Galactosamina/análisis , Heparina/química , Espectroscopía de Resonancia Magnética/métodos , Algoritmos , Animales , Análisis de los Mínimos Cuadrados , Espectroscopía de Resonancia Magnética/economía , Análisis Multivariante , Análisis de Regresión
16.
Anal Chem ; 82(23): 9865-70, 2010 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-21069966

RESUMEN

Here we report results from the analyses by enzymatic digestion and reversed-phase ion-pairing liquid chromatography mass spectrometry (RPIP-LC-MS) of active pharmaceutical ingredient (API) unfractionated heparins (UFHs) from six different manufacturers and one USP standard sample. We employed a reverse phase ion-pairing chromatography method using a C(18) column and hexylamine as the ion-pairing reagent with acetonitrile gradient elution to separate disaccharides generated from the digestion of the heparins by lyase I and III (E.C. 4.2.2.7 and 4.2.2.8) before introduction into an ion-trap mass spectrometer by an electrospray ionization (ESI) interface. Extracted ion chromatograms (EICs) were used to determine the relative abundance of the disaccharides by mass spectrometry. Eight disaccharides were observed and a similar composition profile was observed from digests of 20 UFH samples. The compositional profile determined from these experiments provides a measure of the norm and range of variation in "good" heparin to which future preparations can be compared. Furthermore, the profile obtained in the RPIP-LC-MS assay is sensitive to the presence of the contaminant, oversulfated chondroitin sulfate A (OSCS), in heparin.


Asunto(s)
Cromatografía de Fase Inversa/métodos , Heparina/química , Espectrometría de Masa por Ionización de Electrospray/métodos , Sulfatos de Condroitina/química , Disacáridos/química , Liasa de Heparina/metabolismo , Polisacárido Liasas/metabolismo
17.
Nat Biotechnol ; 26(6): 669-75, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18437154

RESUMEN

Recently, certain lots of heparin have been associated with an acute, rapid onset of serious side effects indicative of an allergic-type reaction. To identify potential causes for this sudden rise in side effects, we examined lots of heparin that correlated with adverse events using orthogonal high-resolution analytical techniques. Through detailed structural analysis, the contaminant was found to contain a disaccharide repeat unit of glucuronic acid linked beta1-->3 to a beta-N-acetylgalactosamine. The disaccharide unit has an unusual sulfation pattern and is sulfated at the 2-O and 3-O positions of the glucuronic acid as well as at the 4-O and 6-O positions of the galactosamine. Given the nature of this contaminant, traditional screening tests cannot differentiate between affected and unaffected lots. Our analysis suggests effective screening methods that can be used to determine whether or not heparin lots contain the contaminant reported here.


Asunto(s)
Sulfatos de Condroitina/análisis , Sulfatos de Condroitina/química , Contaminación de Medicamentos/prevención & control , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Heparina/análisis , Heparina/química , Evaluación Preclínica de Medicamentos , Humanos
18.
N Engl J Med ; 358(23): 2457-67, 2008 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-18434646

RESUMEN

BACKGROUND: There is an urgent need to determine whether oversulfated chondroitin sulfate (OSCS), a compound contaminating heparin supplies worldwide, is the cause of the severe anaphylactoid reactions that have occurred after intravenous heparin administration in the United States and Germany. METHODS: Heparin procured from the Food and Drug Administration, consisting of suspect lots of heparin associated with the clinical events as well as control lots of heparin, were screened in a blinded fashion both for the presence of OSCS and for any biologic activity that could potentially link the contaminant to the observed clinical adverse events. In vitro assays for the activation of the contact system and the complement cascade were performed. In addition, the ability of OSCS to recapitulate key clinical manifestations in vivo was tested in swine. RESULTS: The OSCS found in contaminated lots of unfractionated heparin, as well as a synthetically generated OSCS reference standard, directly activated the kinin-kallikrein pathway in human plasma, which can lead to the generation of bradykinin, a potent vasoactive mediator. In addition, OSCS induced generation of C3a and C5a, potent anaphylatoxins derived from complement proteins. Activation of these two pathways was unexpectedly linked and dependent on fluid-phase activation of factor XII. Screening of plasma samples from various species indicated that swine and humans are sensitive to the effects of OSCS in a similar manner. OSCS-containing heparin and synthetically derived OSCS induced hypotension associated with kallikrein activation when administered by intravenous infusion in swine. CONCLUSIONS: Our results provide a scientific rationale for a potential biologic link between the presence of OSCS in suspect lots of heparin and the observed clinical adverse events. An assay to assess the amidolytic activity of kallikrein can supplement analytic tests to protect the heparin supply chain by screening for OSCS and other highly sulfated polysaccharide contaminants of heparin that can activate the contact system.


Asunto(s)
Anafilaxia/inducido químicamente , Sulfatos de Condroitina/análisis , Sulfatos de Condroitina/farmacología , Activación de Complemento/efectos de los fármacos , Contaminación de Medicamentos , Heparina/química , Calicreínas/efectos de los fármacos , Animales , China , Sulfatos de Condroitina/efectos adversos , Complemento C3a/biosíntesis , Complemento C3a/efectos de los fármacos , Complemento C5a/biosíntesis , Complemento C5a/efectos de los fármacos , Industria Farmacéutica , Femenino , Alemania , Heparina/efectos adversos , Humanos , Hipotensión/inducido químicamente , Calicreínas/metabolismo , Persona de Mediana Edad , Sus scrofa , Estados Unidos , United States Food and Drug Administration
20.
Adv Drug Deliv Rev ; 59(1): 64-72, 2007 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-17196703

RESUMEN

Impurities in drug substances and drug products have been important regulatory issues in the Office of Generic Drugs by having significant impact on the approvability of Abbreviated New Drug Application (ANDAs). This review begins with a discussion of ANDAs and its similarity/differences with NDAs, highlighting the importance of control of pharmaceutical impurities in generic drug product development and regulatory assessment. An overview of the FDA draft guidance documents "ANDAs: Impurities in Drug Substances" and "ANDAs: Impurities in Drug Products" are provided. This introduces the identification and qualification procedures for ANDAs and approaches to the establishment of acceptance criteria for both drug substance and drug product. Case studies included in this review illustrate the proposed pathway for determination of impurities and their acceptance criteria, based upon the general principles of these guidances.


Asunto(s)
Aprobación de Drogas , Contaminación de Medicamentos/legislación & jurisprudencia , Medicamentos Genéricos , Contaminación de Medicamentos/prevención & control , Medicamentos Genéricos/análisis , Estados Unidos , United States Food and Drug Administration
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...